SL
Slope
Unit s
Setting range 0.1 - 9.9
Factory setting 1.0
I-E
I (current) - End - Final current
Unit % (of starting current)
Setting range 0 - 200
Factory setting 50
t-S
time - Starting current - Starting current duration
Unit s
Setting range OFF or 0.1 - 9.9
Factory setting OFF
t-E
time - End current - Final current duration
Unit s
Setting range OFF or 0.1 - 9.9
Factory setting OFF
In the MIG/MAG welding section, the parameters for "Special 2-step mode for robot inter-
face" are illustrated by means of a diagram.
Welding paramet-
ers for "Special
4-step mode" in
the Mode setup
menu
I-S
I (current) - Starting current
Unit % (of starting current)
Setting range 0 - 200
Factory setting 135
SL
Slope
Unit s
Setting range 0.1 - 9.9
Factory setting 1.0
I-E
I (current) - End - Final current
Unit % (of starting current)
Setting range 0 - 200
Factory setting 50
150