Care, maintenance and disposal
General remarks Under normal operating conditions, the wire-feed unit requires only a minimum of care
and maintenance. However, some important points must be noted to ensure that the wel-
ding system remains in a usable condition for many years.
WARNING!
Danger from electrical current.
This can result in serious personal injury and damage to property.
▶
Before starting work, switch off all devices and components involved and disconnect
them from the grid.
▶
Secure all devices and components involved so they cannot be switched back on.
▶
After opening the device, use a suitable measuring instrument to check that electri-
cally charged components (such as capacitors) have been discharged.
Every start-up - Check welding torch, interconnecting hosepack and grounding (earthing) connection
for signs of damage
- Perform a visual check on the feed rollers and inner liner for signs of damage
- Check contact pressure of feed rolls and adjust if necessary
- Check that all screw connections between the robot, wirefeeder mount and wire-
feed unit are secure.
Every 6 months - Dismantle device side panels and clean inside of device with dry, reduced compres-
sed air
CAUTION!
Danger due to the effect of compressed air.
This can result in damage to property.
▶
Do not bring the air nozzle too close to electronic components.
Disposal Dispose of in accordance with the applicable national and local regulations.
57