Number
Control
Indicator
Function
(1) Parameter selection button (left)
for selecting the parameters listed below. 
The corresponding indicator lights up when a parameter is select-
ed.
Material thickness *)
in mm or inches
Current *)
current in A
Before the start of welding, the machine automatically displays a 
standard value based on the programmed parameters. During 
welding, the actual value is displayed.
Wire feed speed *)
in m/min or ipm
Special function 
can only be selected if the SP welding process and the LSC or 
PMC special program has first been selected using the "Welding 
process" button (5).
The following process control parameters can be selected and ad-
justed on all devices:
- Penetration stabiliser
- Arc length stabiliser
As soon as F1 is selected, the current adjustable process control 
parameter is marked with an arrow on the display. Press the "Pa-
rameter selection" button (left) (1) again to select the second pro-
cess control parameter.
The following special functions can be selected depending on the 
configuration.
*) = Synergic parameter
When a synergic parameter is changed, the synergic function au-
tomatically changes all other synergic parameters to match.