EasyManua.ls Logo

Fronius TPS 320i - User Manual

Fronius TPS 320i
228 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
/ Perfect Charging / Perfect Welding / Solar Energy
42,0426,0114,EN 025-11012018
TPS 320i / 400i / 500i / 600i
TPS 400i LSC ADV
Operating Instructions
MIG/MAG Power source
EN

Table of Contents

Questions and Answers

  • K
    Kenneth HernandezAug 16, 2025
    What to do if there is no welding current in my Fronius TPS 320i Welding System?
    • E
      Elizabeth BatesAug 16, 2025
      If your Fronius Welding System shows no welding current, first, check the grounding connection and terminal for correct polarity. If the grounding is correct, the issue might be a break in the current cable within the welding torch, requiring you to replace the welding torch.
  • S
    Stacie ClarkAug 19, 2025
    Why is there no protective gas shield in my Fronius TPS 320i Welding System?
    • J
      Joseph ParkerAug 19, 2025
      If your Fronius Welding System isn't providing a protective gas shield, start by changing the gas cylinder. If the issue persists, the gas pressure regulator may be faulty and require replacement. Also, check the gas hose for proper connection, damage, or kinks, and connect/replace it or straighten out any kinks. If those steps don't solve the problem, the welding torch or gas solenoid valve might be faulty and need to be changed.
  • L
    Lisa HatfieldAug 21, 2025
    How to troubleshoot a Fronius TPS 320i Welding System power source that does not function?
    • S
      sophiatorresAug 21, 2025
      If your Fronius Welding System's power source isn't functioning, begin by checking the mains lead and ensuring the mains plug is securely plugged in. If the problem persists, examine the mains socket and plug for faults, replacing any defective parts. Finally, inspect the mains fuse and change it if it's faulty.
  • A
    Alicia RodriguezAug 25, 2025
    What causes poor weld properties in a Fronius Welding System and how to fix it?
    • R
      Ronald CortezAug 26, 2025
      If your Fronius Welding System is producing poor weld properties, verify the welding parameters are correct. Ensure a good grounding connection to the workpiece. Check for an adequate protective gas shield by inspecting the pressure regulator, gas hose, gas solenoid valve, and torch gas connection. Replace the welding torch if it's leaking, and replace the contact tip if it's wrong or worn out. Finally, check the wire electrode and the weldability of the base metal, and use the correct shielding gas for the wire alloy.
  • R
    Robert MackAug 28, 2025
    What to do if nothing happens when torch trigger is pressed on my Fronius Welding System?
    • J
      Joseph RodgersAug 28, 2025
      If nothing happens when you press the torch trigger on your Fronius Welding System, first ensure the control plug is securely plugged in. If the issue continues, the welding torch or its control line may be faulty and need replacement. Also, check the interconnecting hosepack for faults or improper connection.
  • L
    Lynn BrownAug 30, 2025
    Why is there no welding current in my Fronius Welding System?
    • A
      Andrew MooreAug 31, 2025
      If your Fronius Welding System has no welding current, check the duty cycle. If the duty cycle has been exceeded, let the power source cool down. If the thermostatic automatic circuit breaker has tripped, wait for the power source to automatically come back on after the cooling phase. Ensure accessibility to cooling-air ducts. If the fan in the power source is faulty, it should be replaced by After-Sales Service.
  • J
    James HicksSep 2, 2025
    How to fix irregular wire feed speed on my Fronius TPS 320i?
    • K
      Kaitlin WrightSep 3, 2025
      If your Fronius Welding System has an irregular wire feed speed, try loosening the brake if the braking force has been set too high. Use a suitable contact tip if the hole in the current one is too narrow. Check the inner liner in the welding torch for kinks or dirt. Use suitable feed rollers for the wire electrode being used, and optimise the contact pressure of the feed rollers.
  • R
    Robert WilliamsSep 6, 2025
    Why does the welding torch become very hot on my Fronius TPS 320i Welding System?
    • A
      Amy LopezSep 6, 2025
      If the welding torch of your Fronius Welding System becomes very hot, observe the duty cycle and loading limits of the welding torch. If you are using a water-cooled machine, check the coolant fill level, coolant flow, and for coolant contamination.
  • M
    Melissa DoughertySep 9, 2025
    What to do if my Fronius Welding System has no welding current?
    • D
      dianejohnsonSep 9, 2025
      If your Fronius Welding System has no welding current, several factors could be the cause. First, the duty cycle may have been exceeded, so check it. Second, the thermostatic automatic circuit breaker might have tripped; in that case, wait for the power source to automatically restart after the cooling phase. Third, ensure that the cooling-air ducts are accessible, as a limited supply of cooling air can cause this issue. Finally, the fan in the power source could be faulty, requiring replacement by After-Sales Service.
  • J
    Joseph TurnerSep 12, 2025
    Why my Fronius Welding System power source does not function?
    • S
      Sarah StoneSep 12, 2025
      If your Fronius Welding System's power source isn't functioning, there are several potential causes. It could be due to a break in the mains lead, or the mains plug might not be properly plugged in; in this case, check the mains lead and ensure the plug is connected. Alternatively, the mains socket or plug could be faulty, requiring replacement. Lastly, the mains fuse might be faulty, necessitating a change of the mains fuse protection.

Summary

Safety Rules

General

General safety principles for operating the device, including operator qualifications and device notices.

Proper use

Guidelines for using the device strictly for its intended purpose and never for improper uses.

Protecting yourself and others

Risks associated with welding like sparks, arc radiation, EMF, and necessary protective clothing.

Danger from toxic gases and vapours

Hazards from welding fumes and vapours, and requirements for ventilation or respiratory protection.

Installation and commissioning

MIG;MAG modes

Job mode

Troubleshooting and maintenance

Troubleshooting

Guidance on identifying and resolving malfunctions, warnings, and status codes.

Safety

Crucial safety precautions before opening the device or performing checks.

MIG;MAG welding - Current limit

Explanation of the current limit safety function and corrective measures.

Technical data

Fronius TPS 320i Specifications

General IconGeneral
Power SourceInverter
Input Voltage3 x 400 V
Mains Voltage3 x 400 V
Protection ClassIP 23
Output Current Range (TIG)3 - 320 A
Output Current Range (MMA)10 - 320 A

Related product manuals