72
The confirmation step of the filler metal wizard is displayed:
Select "Save" / press the adjusting dial
The selected filler metal and associated characteristics per welding process will be saved.
Setting the weld-
ing parameters
Select "Welding"
Select the desired welding parameter by turning the adjusting dial
Press the adjusting dial to change the welding parameter
The value of the welding parameter is displayed as a horizontal scale:
e.g. wire speed parameter
The value of the selected parameter can now be changed.
Turn the adjusting dial to change the welding parameter
The adjusted value of the welding parameter is applied immediately.
If one of the "Wire speed", "Material thickness", "Current" or "Voltage" parameters is
changed during synergic welding, the other welding parameters are immediately adjusted
accordingly.
Press the adjusting dial to call up the welding parameters overview
Adjust the process parameters accordingly to make user- or application-specific set-
tings on the welding system
15
1
2
3
1
2
3
4
4
5
6

Table of Contents