74
MIG/MAG and CMT welding parameters
Welding parame-
ters for MIG/MAG
pulse synergic
welding, for CMT
welding and PMC
welding
The following welding parameters for MIG/MAG pulse synergic welding, CMT welding and
PMC welding can be set and displayed by pressing the "Welding" button:
Current
1)
Unit A
Setting range Depends on the welding process and welding program selected
Before the start of welding, the machine automatically displays a standard value based
on the programmed parameters. The actual value is displayed during welding.
Voltage
1)
Unit V
Setting range Depends on the welding process and welding program selected
Before the start of welding, the machine automatically displays a standard value based
on the programmed parameters. The actual value is displayed during welding.
Material thickness
1)
Unit mm in.
Setting range 0.1 - 30.0 mm
2)
0.004 - 1.18
2)
Wire speed
1)
Unit m/min ipm
Setting range 0.5 - max.
2) 3)
19.69 - max
2) 3)
Arc length correction
For correcting the arc length
Setting range -10 - +10
Factory setting 0
- shorter arc length
0 neutral arc length
+ longer arc length
Pulse/dynamic correction
For correcting the pulsing energy of a pulsed arc
Setting range -10 - +10
Factory setting 0
- lower droplet detachment force
0 neutral droplet detachment force
+ higher droplet detachment force