Mode Setup: Acti-
vating the special
4-step mode
"Guntrigger",
special display
for JobMaster
and torch trigger
job selection
In the default settings, the following special functions can be set under "Mode Setup":
- Special 4-step mode "Guntrigger" for a JobMaster welding torch *
- JobMaster special display for a JobMaster welding torch *
- Torch trigger job selection for a welding torch
* Only if the OPT/i GUN Trigger option is available on the power source.
Select "Defaults"
Select "System"
Select "Mode Setup"
The "Mode Setup" overview appears.
Turn the adjusting dial and select the desired special function (white background)
Press the adjusting dial (blue background)
Turn the adjusting dial to activate/deactivate the special function
Select "OK"
The default settings are displayed.
Special 4-step = Guntrigger
With a JobMaster welding torch and with special 4-step mode selected, this function allows
you to change jobs via the torch trigger during welding. Job changing takes place within
defined job groups.
A job group is defined by the next non-programmed job.