Documentation
Documentation The welding data for the last 100 welding operations is displayed in the Documentation en-
try.
The welding data display can be filtered by a certain period using the "Time filter" button.
To do so, the date (yyyy mm dd) and time (hh mm) are entered in the format from – to in
each case.
An empty filter loads the latest welding operations again.
The following data is displayed:
Further values can be displayed by clicking on the "Insert column" button:
-I max / I min: maximum/minimum welding current in A
- Max power / Min power: maximum/minimum arc power in W
- Start time (power source time); date and time
- U max / U min: maximum/minimum welding voltage in V
- Vd max / Vd min: maximum/minimum wire speed in m/min
If the OPT/i documentation option is available on the power source, individual welding sec-
tions can also be displayed.
This documentation can be exported in the desired format
using the "PDF" and "CSV" buttons.
In order to create CSV exports, the OPT/i documentation
option must be available on the power source.
(1) Welding operation number
(2) Start time (date and time)
(3) Welding duration in s
(4) Welding current in A
(5) Welding voltage in V
(6) Wire speed in m/min
(7) IP – arc power in W
(8) IE – arc energy in kJ
(1) (2) (3) (4) (5) (6) (7) (8)