Further information on optimising jobs can be found in the Job correction limits section, un-
der Job Mode on page 86.
Process parame-
ters for "Save as
Job" pre-settings
After confirming the displayed information, the following process parameters can be set for
the "Save as Job" pre-settings:
Lower arc length correction limit
For setting the lower arc length correction limit for a job
Unit -
Setting range -10.0 - 0.0
Factory setting 0
Jobslope - Pre-settings
Jobslope
Defines the time between the job that is currently selected and the next job
Unit s
Setting range 0.0 - 10.0
Factory setting 0
Limit monitoring - Pre-settings
(only in conjunction with the OPT/i Limit Monitoring option)
Lower voltage limit
For setting the lower voltage limit as a function of the set value
Unit V
Setting range -10.0 - 0.0
Factory setting 0
Upper voltage limit
For setting the upper voltage limit as a function of the set value
Unit V
Setting range 0.0 - 10.0
Factory setting 0
Maximum duration of voltage deviation
For setting the maximum duration of a voltage deviation
Unit s
Setting range off / 0.1 - 10.0
Factory setting off
Lower current limit
For setting the lower current limit as a function of the set value
Unit A
Setting range -100.0 - 0.0
Factory setting 0