Upper current limit
For setting the upper current limit as a function of the set value
Unit A
Setting range 0.0 - 100.0
Factory setting 0
Maximum duration of current deviation
For setting the maximum duration of a current deviation
Unit s
Setting range off / 0.1 - 10.0
Factory setting off
Lower wire speed limit
For setting the lower wire speed limit
Unit m/min (ipm)
Setting range -10.0 - 0.0
Factory setting 0
Upper wire speed limit
For setting the upper wire speed limit
Unit m/min (ipm)
Setting range 0.0 - 10.0
Factory setting 0
Maximum duration of wire speed deviation
For setting the maximum duration of a wire speed deviation
Unit s
Setting range off / 0.1 - 10.0
Factory setting off
Response to violation of limit values
For setting the reaction if the limit values are exceeded or undercut
Unit -
Setting range ignore / warning / error
Factory setting 0
ignore Limit values will not be monitored or logged in the logbook
warning If the limit values are exceeded or undercut, a warning will show
on the display and the welding process will not be interrupted.
error If the limit values are exceeded or undercut, the welding pro-
cess will stop immediately and an error message will show on
the display.