125
EN
Process parameters, Job
Optimising job
process parame-
ters
The following process parameters can be set for the job:
Job parameter
The other adjustable process parameters correspond to the process parameters already
described:
Torch mode
For setting the welding mode
Unit -
Setting range 2-step / 4-step / S2-step / S4-step
Wire speed
For adjusting the wire speed
Unit m/min (ipm)
Setting range For example: 2 - 25
(depending on wire speed and welding characteristic)
Arc length correction
For correcting the arc length
Unit -
Setting range -10.0 - +10.0
- short arc
0 uncorrected arc length
+ longer arc
Pulse/Arc-force dynamic correction
For correcting the pulse energy during pulsed arc welding
Setting range -10.0 - +10.0
- lower droplet detachment force
0 neutral droplet detachment force
+ higher droplet detachment force
For influencing the short-circuiting dynamic at the moment of droplet transfer during
standard arc welding
- harder, more stable arc
0 neutral arc
+ soft, low-spatter arc