EasyManua.ls Logo

Fronius WF 15i - Page 56

Fronius WF 15i
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
Power source has no function
Mains switch is on, but indicators are not lit up
Cause: There is a break in the mains lead; the mains plug is not plugged in
Remedy: Check the mains lead, ensure that the mains plug is plugged in
Cause: Mains socket or mains plug faulty
Remedy: Replace faulty parts
Cause: Mains fuse protection
Remedy: Change the mains fuse protection
Nothing happens when the torch trigger is pressed
Power source mains switch is ON and indicators are lit up
Cause: Only for welding torches with an external control plug: The control plug is not
plugged in
Remedy: Plug in the control plug
Cause: Welding torch or welding torch control line is faulty
Remedy: Replace welding torch
No welding current
Mains switch is ON and indicators are lit up
Cause: Grounding (earthing) connection is incorrect
Remedy: Check the grounding (earthing) connection for correct polarity
Cause: There is a break in the power cable in the welding torch
Remedy: Replace the welding torch
No protective gas shield
All other functions are OK
Cause: Gas cylinder is empty
Remedy: Change the gas cylinder
Cause: The gas pressure regulator is faulty
Remedy: Replace the gas pressure regulator
Cause: Gas hose is not fitted or is damaged
Remedy: Fit or change the gas hose
Cause: Welding torch is faulty
Remedy: Change the welding torch
Cause: Gas solenoid valve is faulty
Remedy: Contact After-Sales Service

Table of Contents