56
Power source has no function
Mains switch is on, but indicators are not lit up
Cause: There is a break in the mains lead; the mains plug is not plugged in
Remedy: Check the mains lead, ensure that the mains plug is plugged in
Cause: Mains socket or mains plug faulty
Remedy: Replace faulty parts
Cause: Mains fuse protection
Remedy: Change the mains fuse protection
Nothing happens when the torch trigger is pressed
Power source mains switch is ON and indicators are lit up
Cause: Only for welding torches with an external control plug: The control plug is not
plugged in
Remedy: Plug in the control plug
Cause: Welding torch or welding torch control line is faulty
Remedy: Replace welding torch
No welding current
Mains switch is ON and indicators are lit up
Cause: Grounding (earthing) connection is incorrect
Remedy: Check the grounding (earthing) connection for correct polarity
Cause: There is a break in the power cable in the welding torch
Remedy: Replace the welding torch
No protective gas shield
All other functions are OK
Cause: Gas cylinder is empty
Remedy: Change the gas cylinder
Cause: The gas pressure regulator is faulty
Remedy: Replace the gas pressure regulator
Cause: Gas hose is not fitted or is damaged
Remedy: Fit or change the gas hose
Cause: Welding torch is faulty
Remedy: Change the welding torch
Cause: Gas solenoid valve is faulty
Remedy: Contact After-Sales Service