1.8.4 Leaking
Leakage of the frypot almost always will be due to improperly sealed high-limits, thermostats, or
drain fittings. When installed or replaced, each of these components must be sealed with Loctite™
PST56765 sealant or equivalent to prevent leakage. In very rare cases, a leak may develop along
one of the welded edges of the frypot. When this occurs, the frypot must be replaced.
If the sides and/or ends of the frypot are coated with oil/shortening, the most likely cause is spillage
over the top of the frypot rather than leakage.
1.9 Wiring Diagram
1.9.1 Current Production Units with Honeywell Gas Valve
2C
1C
High-Limit Thermostat
Thermopile
Operating Thermostat
PP
TH
PP
TH