4-8
WARNING
The filter pump is equipped with a manual reset switch in case the filter motor overheats or
an electrical fault occurs. If this switch trips, turn off power to the filter system and allow
the pump motor to cool 20 minutes before attempting to reset the switch (see photo
below). To access the switch, reach in from the front of the fryer.
Filter Pump Reset Switch (Arrow)
7. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not
operate.) Turn the fryer ON and allow the cooking oil to reach setpoint.
DANGER
The crumb screen in fryers equipped with a filter system must be emptied into a fireproof
container at the end of frying operations each day. Some food particles can spontaneously
combust if left soaking in certain shortening material.
WARNING
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to
seal the joint between the fry vessels. Banging fry baskets on the strip to dislodge
shortening will distort the strip, adversely affecting its fit. It is designed for a tight fit and