Command: IHRE sclr?
Description:
Input Right Edge Inquiry.
Parameters:
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
IHRE A?: Returns the pixel location of the Right Edge.
Command: IHUE nnn sclr
Description:
Adjusts the Input Hue setting.
(Only applicable if input is a NON-RGB source.)
Parameters:
nnn - Input Hue Selection; n[0 - 360]degrees
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
IHUE 20 A: Adjusts the Input Hue selection on Scaler A to be 20 degrees.
Command: IHW sclr?
Description:
Input Horizontal Width Inquiry.
Parameters:
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
IHW A?: Returns the total pixel width of the input on Scaler A.
Command: IRSP op nnn sclr
Description:
Adjusts the Input Raster Size/Position.
Parameters:
op - Select Raster Control; [L|R|T|B] Left, Right, Top, Bottom
nnn - Increment/Decrement value; [-999 – 999]
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
IRSP R 10 A: Increments the Right Input Raster Size/Position by 10 on Scaler A.
Command: ISAT nnn sclr
Description:
Adjusts the Input Color Balance Saturation.
(Only applicable if input is a NON-RGB source.)
Parameters:
nnn - Input Saturation: n[50-200]%
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
ISAT 110.0 A: Adjusts the Input Color Balance to 110.0%.
Command: ISYNC n sclr