Number to Increment by when op = I
Example:
ICPL A P: Automatically adjust the number of Input Clocks per
line on Preview.
ICPL M M 1364: Set Input Clocks per Line on Main to 1364.
ICPL I A 4: Increment the number of Input Clocks per Line on
Scaler A by 4.
Command: ICREC nn sclr
Description:
Recalls a stored Input Configuration.
Parameters:
nn - Input Configuration Index; n[1 - 64]
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
n - Router input to which the input signal is connected.
Note: Router Input parameter only used on Compass S2 Plus.
Example:
(Assuming there is a saved Input Configuration in Index #1)
ICREC 1 M: Loads the Input Configuration stored in Index #1 to the
source on Main.
ICREC 1 A 2: Loads the Input Configuration stored in Index #1 on Scaler
A. In this example the input signal is sourced on router
input 2.
Command: ICRST sclr
Description:
Resets the current input configuration of the scaler specified.
Parameters:
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
ICRST A: Reset the input configuration for Scaler A.
Command: ICSAV nn s[8] sclr
Description:
Saves an Input Configuration to a specified index.
Parameters:
nn - Input Configuration Index; n[1 - 64]
s[8] - Input Configuration Name; s[Name] (Up to 8 characters, no spaces)
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
ICSAV 1 TEST A: Saves the input configuration currently on Scaler A to Index #1 with the label
name TEST.
Command: ICSP n sclr
Description:
Adjusts the Input Color Space mode.
Parameters:
n - Color Space Selection; [0 – 6] RGB|B50|B60|MII|EBU|NTSC|SVID
If n = 254 or 255, then selection will increment or decrement through the list.
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
ICSP 0 A: Adjusts the Input Color Space on Scaler A to be RGB.
44 Compass S
2