Adjusts the Input Contrast values.
Parameters:
op - Select Contrast Control;
[C|R|G|B] Common, Red Offset, Green Offset, Blue Offset
nnn - Contrast value, C Range 75 - 125%, RGB Range -25 - 25%
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
ICNT C 100.8 A: Adjusts the Common Input Contrast value as 100.8%.
ICNT G 15: Adjusts the Green Contrast Offset to 15% on Scaler A.
Command: ICPH op sclr nn
Description:
Adjust the Input Clock Phase.
Parameters:
op - [A|D|M|I] Automatic | Debug | Manual | Increment
Note: Debug Mode is for Factory Use Only
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
nn Phase Number [0 – 31] when op = M
Number to Increment by when op = I
nn File Number [0 – 64]
Example:
ICPH A P: Automatically adjust the Input Clock Phase on Preview.
ICPH M M 12 0: Set Input Clock Phase on Main to 12 for the currently displayed input.
ICPH M M 12 2: Set Input Clock Phase for File Number 2 to 12.
ICPH I A 3: Increment the Input Clock Phase on Scaler A by 3.
Command: ICPHO op sclr nn
Description:
Adjust the Input Clock Phase Offset.
Parameters:
op - [A|D|M|I] Automatic | Debug | Manual | Increment
Note: Debug Mode is for Factory Use Only
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
nn Phase Offset Number [-16 – 16] when op = M
Number to Increment by when op = I
nn File Number [0 – 64]
Example:
ICPHO A P: Automatically adjust the Input Clock Phase Offset on
Preview.
ICPHO M M 12 0: Set Input Clock Phase Offset on Main to 12 for the currently displayed input.
ICPHO M A 12 2: Set Input Clock Phase Offset for File Number 2 to 12. If the scaler A source
displayed is derived from File Number 2, it will be updated as well.
ICPHO I A 3: Increment the Input Clock Phase Offset on Scaler A by 3.
Command: ICPL op sclr nnnn
Description:
Adjust the number of Input Clocks per Line.
Parameters:
op - [A|D|M|I] Automatic | Debug | Manual | Increment
Note: Debug Mode is for Factory Use Only
sclr - Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
nnnn – Number of Clocks per Line [0 – 4096] when op = M