33
Setting of decimal point position (Setting range: 0 to 2)
[Description]
Decimal point position can be set on
LED display.
Example) Altering the measuring range 0150°C to 0.0
150°C
Key operation Description
Press the SEL key for 3 seconds,
and P-n1 is displayed.
Press the SEL key repeatedly until
P-dP is displayed.
Press the or key to display
1.
0 is displayed and it is clear that
none below decimal point is set.
Press the SV key when you need to
display the operation status display.
After pressing the ENT key, the data
is registered.
Display
SEL
SEL
SV
DATA
ENT
Related parameter: P-SL (Page 29)
P-SU (Page 29)
Below decimal point
1 digit below decimal point
2 digit below decimal point
0
1
2