3.3.4 Jogging (inching) the motor (Available only in FRENIC-Ace)
To start jogging operation, perform the following procedure.
(1) Make the inverter ready to jog with the steps below.
1) Switch the inverter to Running mode (see Section 3.2).
2) Press the "
+
keys" simultaneously.
Function code C20 specifies the jogging frequency. H54 and H55 specify the acceleration
and deceleration times, respectively. These three function codes are exclusive to jogging
operation. Configure each function code, if needed.
Using the input terminal command JOG ("Ready for jogging") switches between the normal
operation state and ready-to-jog state.
• Switching between the normal operation state and ready-to-jog state with the "
+
keys" is possible only when the inverter is stopped.
(2) Jog the motor.
While the
or
key is held down, the motor continues jogging. Releasing the key decelerates the
motor to a stop.
(3) Make the inverter exit from the ready-to-jog state and return to the normal operation state.
Press the "
+ keys" simultaneously.
Figure 3.5 Screen Sample in Jogging Operation
3.3.5 Switching between the remote and local modes
The inverter is available in either remote or local mode.
In remote mode, run and frequency command sources are selected by function codes. In local mode, the
command sources specified from the keypad are enabled, regardless of the settings made by function codes.
For details, refer to Section 3.5.2 "Remote and local modes."
Holding down the
key on the keypad for 2 seconds or more switches between remote and local modes.
Switching these modes is also possible by a digital input signal provided from the outside of the inverter. You
need to assign LOC ("Select local (keypad) operation") as a digital input signal to any of digital input terminals.
( Refer to E01 through E07.)
The current mode can be checked by the status icons. The / /
is displayed in
remote mode and the , in local mode.
Switching from remote to local mode automatically inherits the frequency settings used in remote mode. If the
motor is running at the time of the switching from remote to local, the run command will be automatically turned
ON so that all the necessary data settings will be carried over. If, however, there is a discrepancy between the
settings used in remote mode and ones made on the keypad (e.g., switching from the reverse rotation in
remote mode to the forward-only rotation in local mode), the inverter automatically stops.