Cleaning the Machine
81
Maintenance
3
Cleaning White Chute and Constant Velocity Transport Glass
If the white chute or the constant velocity transport glass become soiled, smudges may
appear on copies, faxes, or scanned documents and the machine may not properly detect
document sizes.
To ensure clean copies at all times, clean white
chute and the constant velocity transport glass
about once a month with the cloth provided in
the document feeder as shown in the
illustration.
Important • Do not use benzene, paint thinner, or other
organic solvents. Doing so might damage
paint or coating on plastic parts.
• Cleaning the machine with an excessive
amount of water may cause the machine to
malfunction or damage documents during
copying, faxing, or scanning.
1
Lift the document feeder gently, and open the
Side 2 scanner.
2
Wipe the white chute with the provided cloth.
Note • If you cannot remove dirt easily, gently wipe
the white chute with a soft cloth moistened
with a small amount of neutral detergent.
Important • Do not press the film with an excessive force
as it can be easily damaged.
• Do not use cleaning agents other than water
or neutral detergent.
3
Wipe the Side 1 constant velocity transport
glass and the Side 2 constant velocity transport
glass with the provided cloth.
Note • If you cannot remove dirt easily, gently wipe
the glass with a soft cloth moistened with a
small amount of neutral detergent.
Important • Do not use cleaning agents other than water
or neutral detergent.