Using the Operator Panel Menus 174
•Adjust BTR
Purpose:
To specify the optimum voltage settings for printing for the transfer roller (BTR). To lower the voltage,
set negative values. To increase, set positive values.
The default settings may not give the best output on all paper types. If you see mottles on the print
output, try to increase the voltage. If you see white spots on the print output, try to decrease the
voltage.
NOTE:
• The print quality changes depending on the values you select for this item.
Values:
• Adj. Fusing Unit
Purpose:
To specify the optimum temperature settings for printing for the fusing unit. To lower the temperature,
set negative values. To increase, set positive values.
The default settings may not give the best output on all paper types. When the printed paper has
curled, try to lower the temperature. When the toner does not fuse on the paper properly, try to
increase the temperature.
NOTE:
• The print quality changes depending on the values you select for this item.
Values:
Plain 0*
-3 – +3
Bond 0*
-3 – +3
Light Card 0*
-3 – +3
Labels 0*
-3 – +3
JP Gloss Card 0*
-3 – +3
LW Gloss Card 0*
-3 – +3
Envelope 0*
-3 – +3
Recycled 0*
-3 – +3
Postcard 0*
-3 – +3
Plain 0*
-3 – +3