External heater output
Control Primary heater Auxiliary heater
Function setting
Indoor unit
Control switching
external heaters No. 61
Auxiliary heater control 1 RAC heat pump
External device
(Hot water electrical
heater, etc.)
61-00
NOTES:
After turning off the heater, 3 minutes of standby time is required by next power-on of the
heater.
For items marked “—” in the table, any of validate or invalidate of the setting are acceptable.
Installation configuration of individual connection
External heating device is installed individually. (No use of indoor unit fan)
ON / OFF
Example of heating device:
- Floor heating device
WARNING
Design and install external heater appropriately with considering its protection.
Inappropriate designing and installation of external heater may cause a fire by emitted heat from
the external heater.
Fujitsu General Ltd. is not responsible for inappropriate designing or installation of external
heating device.
- 23 -
8-4. Details of function 8. External input and output
FLOOR TYPE
AGYG09-14KVCA
FLOOR TYPE
AGYG09-14KVCA