02-50
Test 3 : Check Heater wire.
Black - White
Resistance value e r i w dae R
Test 1 : Check Connections
Check connection of connector
( Loose connector or open cable )
Remove connector, check resistance of Heater wire.
If Resistance value is abnormal, replace Heater Unit.
Test 2 : Check electrical components
Check Check Fuses.
>> If Fuse is open, check connection, and replace Fuse.
320.7 - 367.3
CN9
1 2 3 4
1 2 3 4
BLACK
WHITE
HEATER
FUSE AC250V 5A
THERMOSTAT
at 77°F (25°C)
SERVICE PARTS INFORMATION 6
Heater unit