9. Electrical characteristics
Indoor unit Power supply
Wiring specification *
1
(Total *
2
)
Type Model name
Frequency
(Hz)
Voltage
(V)
MCA
(A)
Connection cable (mm
2
)
Compact
cassette
AUXG18KVLA
230 50
0.2
1.5
AUXG22KVLA 0.3
AUXG24KVLA 0.3
Slim duct ARXG18KLLAP 0.5
Duct
ARXG22KMLA 0.7
ARXG24KMLA 0.7
MCA: Minimum Circuit Amperes = Maximum operating current (Full load)
NOTES:
*1: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
As the regulations of wire size and circuit breaker differ in each country or region, select appro-
priate devices complied to the regional standard.
*2: Total length of all wirings that interconnect between indoor units and between indoor unit
and outdoor unit.
- 49 -