- (02 - 01) -
OUTDOOR UNIT
AO 18-24L2
OUTDOOR UNIT
AO 18-24L2
1. SPECIFICATIONS
MODELS
AO 18L2 : AR 14L, AR 9L
AO 24L2 : AS 18L, AS 12L
THE FOLLOWING PERFORMANCE IS A VALUE AT STANDARD COMBINATIONS.
Heating B A
kW 5.5 5.8
BTU/h 18800 19800
kW 2.0 - 6.5 2.5 - 7.8
BTU/h 6800 - 22200 8500 - 26600
kW 6.4 6.4
BTU/h 21800 21800
kW 2.2 - 7.1 2.2 - 9.0
BTU/h 7500 - 24200 7500 - 30700
Rated
1.73 1.73
Min - Max
0.68 - 2.22 0.80 - 2.77
Rated
1.84 1.64
Min - Max
0.68 - 2.22 0.80 - 2.77
Rated
7.50 7.55
Max
9.70 12.20
Rated
8.00 7.15
Max
9.70 12.20
3.18 3.35
3.48 3.90
A
2800 2800
2800 2800
W
49 49
50 50
W
g
Connect to connection valve by the adapter.
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CWB.
Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 7.5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
MULTI SATTELITE SYSTEM MODEL
9.52 (3/8in.) × 1, 12.70 (1/2in.) × 1
Max. height difference between
Indoor Units.
Max. height difference between
Outdoor Unit and each Indoor Units.