02-01
2-1 ERROR DISPLAY
2-1-1 INDOOR UNIT AND WIRED REMOTE CONTROLLER DISPLAY
Please refer the flashing pattern as follows.
Indoor Unit : AS*G07/ 09/ 12/ 14KGTA
The OPERATION, TIMER and ECONOMY lamps operate as follows according to the error contents.
Error Contents
Continuous1 times 1 times
Trouble
shooting
(Green)
(Orange)
(Green)
Serial communication error
1.2
Indoor Unit Display
Wired Remote
Controller
Display
11
Continuous
1 times
8 times
External Communication Error
3
18
Continuous
2 times
2 times
Indoor Unit Capacity Error
4
22
Continuous
2 times
3 times
Combination Error
5
23
Continuous
2 times
6 times
Indoor Unit Address Setting Error
6
26
Continuous
2 times
9 times
Connection Unit Number Error
(Indoor Unit Wired Remote Controller Error)
7
29
Continuous
3 times
2 times
8
32
Continuous
3 times
3 times
9
33
[ ]
[ ]
[ ]
OPERATION TIMER
ECONOMY
Indoor unit main PCB error
Indoor Unit Motor Electricity
Consumption Detection Error
Continuous
3 times
5 times
10
35
Manual auto switch error
Continuous
4 times
1 times
13
41
Indoor Room Thermistor Error
Continuous
4 times
2 times
14
42
Indoor Heat Ex. Thermistor Error
Continuous
5 times
1 times
15
51
Indoor Unit Fan Motor Error
Continuous
5 times
15 times
2-15
5U
Continuous
6 times
2 times
16
62
Indoor Unit Error
Continuous
3 times
9 times
11
39
Indoor Unit Power Supply Error for
Fan Motor
Continuous
3 times
10 times
12
3A
Indoor Unit Communication Circuit
(Wired Remote Controller) Error
Outdoor unit main PCB error
Continuous
6 times
4 times
18
64
PFC circuit error
Continuous
6 times
5 times
19
65
IPM Error
Continuous
7 times
1 times
21
71
Discharge Thermistor Error
Continuous7 times 4 times
Outdoor Thermistor Error
2374
Continuous7 times 3 times
Heat Ex. Liquid Outlet
Thermistor Error
2273