6. SYSTEM DESIGN
COMPLETION OF FUNCTION SETTING MODE
(11) Press the “RESET” button.
RESET
SETTING UP EACH INDOOR UNIT
Repeat steps (1) through to (11).
RESET THE POWER AFTER SETTING UP FUNCTION OF ALL
INDOOR UNITS
Important
If the reset is not performed, function can not be read in normally.
After all the functions have been set, the circuit breaker needs to be switched off for
at least 2 minutes.
After the 2 minutes has passed, power can be restored.
The set fuction is stored in the PCB and will remain in memory even when the power
is turned off.
However setting function is effective after power reset.
Record the function set in the indoor unit on a label, etc., and afx the label to the
unit so it can be used for after-sales service operations.
Once the "RESET" button is pressed on the remote controller, the OPERATION MODE will be
set in the "AUTO MODE".
Please adjust the OPERATION MODE to either "COOLING" or "HEATING" before trying to
operate the air conditioner.
Note:
If CUSTOM CODE is set to anything other than "A" ,the remote control must be set
accordingly to the INDOOR UNIT setting.
- (06 - 61) -
SYSTEM
DESIGN
SYSTEM
DESIGN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASHG14LMCA and is the answer not in the manual?

Fujitsu ASHG14LMCA Specifications

General IconGeneral
BrandFujitsu
ModelASHG14LMCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals