8-2. External output
Use an external output cable with appropriate external dimension, depending on the number of
cables to be installed.
¢
External input and output PCB
• A twisted pair cable (22AWG) should be used. Maximum length of cable is 25 m.
• Output voltage: High DC 12 V±2 V, Low 0 V.
• Permissible current: 50 mA
• For details, refer to "Combination of external input and output" on page 23.
• When indicator or other components are connected directly:
Example: Function setting 60 is set to "00".
• When connecting with a device equipped with a power supply:
Example: Function setting 60 is set to "00".