EasyManua.ls Logo

Fujitsu ASYG07KGTA - Safety Devices

Fujitsu ASYG07KGTA
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Safety devices
Type of
protection
Protection form
Model
AOYG07KGCA AOYG09KGCA
Circuit protection Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Terminal protection
program
Activate
125±25 °C
Fan motor stop
Reset
100±25 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Type of
protection
Protection form
Model
AOYG12KGCA AOYG14KGCA
Circuit protection Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Terminal protection
program
Activate
125±25 °C
Fan motor stop
Reset
100±25 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
- 59 -
OUTDOOR UNIT
AOYG07-14KGCA

Table of Contents

Other manuals for Fujitsu ASYG07KGTA