Contents of function setting
Each function setting listed in this section is adjustable in accordance with the installation environ-
ment.
NOTE:
Setting will not be changed if invalid numbers or setting values are selected.
Function setting list
Function no. Functions
1) 00 Remote controller address setting
2) 11 Filter sign
3) 30/31 Room temperature control for indoor unit sensor
4) 35/36 Room temperature control for wired remote controller sensor
5) 40 Auto restart
6) 42 Room temperature sensor switching
7) 44 Remote controller custom code
8) 46 External input control
9) 48 Room temperature sensor switching (Aux.)
10) 49 Indoor unit fan control for energy saving for cooling
11) 60 Switching functions for external output terminal
1) Remote controller address setting
NOTE: Because this setting is normally done automatically when 2-wire-type wired remote con-
troller is installed, setting is unnecessary.
Multiple indoor units can be operated by using one wired remote controller.
Set the unit number of each indoor unit.
Function number Setting value Setting description Factory setting
00
00 Unit no. 0
01 Unit no. 1
02 Unit no. 2
03 Unit no. 3
04 Unit no. 4
05 Unit no. 5
06 Unit no. 6
07 Unit no. 7
08 Unit no. 8
09 Unit no. 9
10 Unit no. 10
11 Unit no. 11
12 Unit no. 12
13 Unit no. 13
14 Unit no. 14
15 Unit no. 15
NOTE:
When different type of indoor units (such as wall mounted type and cassette type, cas-
sette type and duct type, or other combinations) are connected using group control sys-
tem, some functions may no longer be available.
- 35 -
WALL MOUNTED
ASYG07-14KGTA