1-4. Rotation number of compressor at normal start-up
¢ Models: AOYG07KMCC, AOYG09KMCC, AOYG12KMCC, and
AOYG14KMCC
Rotation number of compressor soon after starting is controlled as below.
Rotation number I
Rotation number II
Rotation number III
Rotation number IV
Rotation number V
Rotation number VI
Rotation number VII
Time 1
Time 2 Time 3
Time 4
Time 5
Time 6
Time 7
Rotation number (rps)
I II III IV V VI VII
45 56 68 77 84 93 103
Time (sec)
1 2 3 4 5 6 7
60 140 170 220 280 360 430
1-4. Rotation number of compressor at normal start-up - (04-5) - 1. Rotation number control of compressor