EasyManua.ls Logo

Fujitsu ASYG07KMCE - Page 105

Fujitsu ASYG07KMCE
155 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-25°C
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOYG07KMCC
AOYG09KMCC
AOYG12KMCC
A zone 43 rps
B zone 43 rps
C zone 30 rps
D zone 18 rps
E zone 16 rps
F zone 16 rps
AOYG14KMCC
A zone 37 rps
B zone 37 rps
C zone 36 rps
D zone 15 rps
E zone 1 rps
F zone 1 rps
1-5. Limitation of compressor rotation number by outdoor temperature - (04-7) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Related product manuals