EasyManuals Logo

Fujitsu ASYG09KMTA User Manual

Fujitsu ASYG09KMTA
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
2. HEATING OPERATION
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is lower by 6°C than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is some degrees higher than a set temperature,
the compressor will be stopped.
* When the room temperature is between +1°C to -6°C of the setting temperature,
the compressor frequency is controlled within the range shown in Table 3.
( Table 3 : Compressor frequency range )
01-02
Minimum
frequency
Maximum
frequency
14rps 110rps
12rps 110rps
AO*G07KMTA
AO*G09KMTA
AO*G12KMTA
AO*G14KMTA

Other manuals for Fujitsu ASYG09KMTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG09KMTA and is the answer not in the manual?

Fujitsu ASYG09KMTA Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-splitNo
Product colorWhite
Gas hose diameter9.5 mm
Hose length (max)15 m
Inverter technology-
Liquid hose diameter6.35 mm
Comfort sleeping modeYes
Dehumidifying capacity1.3 l/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)3200 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)4000 W
Cooling capacity in watts (nominal)2500 W
Cooling energy efficiency (EER, W/W)3.97
Heating energy efficiency (COP, W/W)4.52
Seasonal efficiency rating (cooling) (SEER)7.4
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)2800 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.1
AC input voltage230 V
Current (cooling)6.5 A
Current (heating)9 A
AC input frequency50 Hz
Design load (cooling)2.5 kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.4 kW
Energy efficiency class (heating) (Average heating season)A+
Indoor unit typeWall-mountable
Indoor unit depth222 mm
Indoor unit width834 mm
Indoor unit height270 mm
Indoor unit weight10000 g
Indoor units quantity1
Cooling airflow (indoor unit)700 m³/h
Indoor unit sound power level40 dB
Indoor unit noise level (low speed)29 dB
Indoor unit noise level (high speed)46 dB
Outdoor unit noise level- dB