EasyManuals Logo

Fujitsu ASYG09KMTA User Manual

Fujitsu ASYG09KMTA
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
01-15
17. COMPRESSOR PREHEATING
18. 10°C HEAT OPERATION
10°C HEAT operation performs as below when pressing 10°C HEAT button or Weekly timer setting on the remote
controller.
Mode Heating
Setting temperature 10°C
Fan mode Auto
LED display Economy
Defrost operation Operate as normal
( Table 18 : 10°C HEAT operation )
19. ECONOMY OPERATION
The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
At the maximum output, ECONOMY Operation is approximately 70% of normal air conditioner operation
for cooling and heating.
The ECONOMY operation is almost the same operation as below settings.
Mode Cooling/ Dry Heating
Target temperature Setting temp.+1°C Setting temp.-1°C
( Table 19 )
When the outdoor heat exchanger temperature is lower than -4°C and the heating operation has
been stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started, and when the outdoor temperature rises to -2°C or greater,
preheating is ended.

Other manuals for Fujitsu ASYG09KMTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG09KMTA and is the answer not in the manual?

Fujitsu ASYG09KMTA Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-splitNo
Product colorWhite
Gas hose diameter9.5 mm
Hose length (max)15 m
Inverter technology-
Liquid hose diameter6.35 mm
Comfort sleeping modeYes
Dehumidifying capacity1.3 l/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)3200 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)4000 W
Cooling capacity in watts (nominal)2500 W
Cooling energy efficiency (EER, W/W)3.97
Heating energy efficiency (COP, W/W)4.52
Seasonal efficiency rating (cooling) (SEER)7.4
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)2800 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.1
AC input voltage230 V
Current (cooling)6.5 A
Current (heating)9 A
AC input frequency50 Hz
Design load (cooling)2.5 kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.4 kW
Energy efficiency class (heating) (Average heating season)A+
Indoor unit typeWall-mountable
Indoor unit depth222 mm
Indoor unit width834 mm
Indoor unit height270 mm
Indoor unit weight10000 g
Indoor units quantity1
Cooling airflow (indoor unit)700 m³/h
Indoor unit sound power level40 dB
Indoor unit noise level (low speed)29 dB
Indoor unit noise level (high speed)46 dB
Outdoor unit noise level- dB