9. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE:
Incorrect settings can cause a product malfunction.
9-1. Function settings by using remote controller
Some function settings can be changed on the remote controller. After confirming the setting proce-
dure and the content of each function setting, select appropriate functions for your installation envi-
ronment.
¢
Setting procedure by using wireless remote controller
The function number and the associated setting value are displayed on the LCD of the remote con-
troller. Follow the instructions written in the local setup procedure supplied with the remote controller,
and select appropriate setting according to the installation environment.
Before connecting the power supply of the indoor unit, reconfirm following items:
Piping air tight test and vacuuming have been performed firmly.
There is no wiring mistake.
Then, connect the power supply of indoor unit.
Entering function setting mode:
While pressing the FAN button and SET TEMP. ( ) button simultaneously, press the RESET button
to enter the function setting mode.
STEP 1: Setting the remote controller custom code
Use the following steps to select the custom code of the remote controller. (Note that the air condi-
tioner cannot receive a custom code if the air conditioner has not been set for the custom code.)
The custom codes that are set through this process are applicable only to the signal in the function
setting.
For details on how to set the custom codes through the normal process, refer to "Custom code set-
ting" on page 22.
1. Press the SET TEMP. (
) ( ) buttons to change the custom code
between . Match the code on the display to the air
conditioner custom code. (Initially set to
.) If the custom code
does not need to be selected, press the MODE button, and pro-
ceed to STEP 2.
2. Press the MODE button to accept the custom code, and proceed to
STEP 2.
*1: Small is displayed on the right of the custom code during the func-
tion setting.
*1
NOTES:
The air conditioner custom code is set to prior to shipment. To change the custom code, con-
tact your retailer.
The remote controller resets to custom code
when the batteries on the remote controller are
replaced. If you use a custom code other than code
, reset the custom code after replacing the
batteries.
If you do not know the air conditioner custom code setting, try each of the custom codes (
) until you find the code that operates the air conditioner.
- 18 -
9-1. Function settings by using remote controller 9. Function settings
WALL MOUNTED
ASYG07-12KPCA
WALL MOUNTED
ASYG07-12KPCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG12KPCA and is the answer not in the manual?

Fujitsu ASYG12KPCA Specifications

General IconGeneral
TypeSplit system
TimerYes
Multi-splitNo
Product colorWhite
Gas hose diameter9.52 mm
Hose length (max)20 m
Inverter technology-
Liquid hose diameter6.35 mm
Dehumidifying capacity1.8 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (nominal)3400 W
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Seasonal efficiency rating (cooling) (SEER)6.3
Seasonal efficiency rating (heating) (SCOP)4.1
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3800 W
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)3.4 kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh
Design load (heating) (Colder heating season)- kW
Design load (heating) (Warmer heating season)1.3 kW
Design load (heating) (Average heating season)2.5 kW
Energy efficiency class (heating) (Average heating season)A+
Indoor unit typeWall-mountable
Indoor unit depth224 mm
Indoor unit width784 mm
Indoor unit height270 mm
Indoor unit weight8000 g
Indoor units quantity1
Cooling airflow (indoor unit)630 m³/h
Indoor unit sound power level59 dB
Indoor unit noise level (low speed)22 dB
Indoor unit noise level (high speed)46 dB
Outdoor unit noise level- dB