2. Dimensions
2-1. Models: AOYG07KPCA, AOYG09KPCA, and AOYG12KPCA
Unit: mm
Airflow
106450
19 663 68 16
33 30
290
353
330
Pitch of bolts for installation
4-
M1
0 hole
Bottom view Side view (Valve part)
Top view
Side view
Side view
Front view
Pitch of bolts
for installation
353
541
20
184
120
37
170
331
Drain port Ø42
- 27 -
2-1. Models: AOYG07KPCA, AOYG09KPCA, and AOYG12KPCA 2. Dimensions
OUTDOOR UNIT
AOYG07-12KPCA
OUTDOOR UNIT
AOYG07-12KPCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG12KPCA and is the answer not in the manual?

Fujitsu ASYG12KPCA Specifications

General IconGeneral
TypeSplit system
TimerYes
Multi-splitNo
Product colorWhite
Gas hose diameter9.52 mm
Hose length (max)20 m
Inverter technology-
Liquid hose diameter6.35 mm
Dehumidifying capacity1.8 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (nominal)3400 W
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Seasonal efficiency rating (cooling) (SEER)6.3
Seasonal efficiency rating (heating) (SCOP)4.1
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3800 W
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)3.4 kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh
Design load (heating) (Colder heating season)- kW
Design load (heating) (Warmer heating season)1.3 kW
Design load (heating) (Average heating season)2.5 kW
Energy efficiency class (heating) (Average heating season)A+
Indoor unit typeWall-mountable
Indoor unit depth224 mm
Indoor unit width784 mm
Indoor unit height270 mm
Indoor unit weight8000 g
Indoor units quantity1
Cooling airflow (indoor unit)630 m³/h
Indoor unit sound power level59 dB
Indoor unit noise level (low speed)22 dB
Indoor unit noise level (high speed)46 dB
Outdoor unit noise level- dB

Related product manuals