3) Auto restart
Enables or disables automatic restart after a power interruption.
Function number Setting value Setting description Factory setting
40
00 Enable
01 Disable
NOTE: Auto restart is an emergency function such as for power outage etc. Do not attempt to use
this function in normal operation. Be sure to operate the unit by remote controller or exter-
nal device.
4) Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed. Select the appropriate custom code.
Function number Setting value Setting description Factory setting
44
00 A
01 B
02 C
03 D
5) Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when the
outdoor unit is stopped during cooling operation.
Function number Setting value Setting description Factory setting
49
00 Disable
01 Enable
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting
on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed.
- 21 -
9-1. Function settings by using remote controller 9. Function settings
WALL MOUNTED
ASYG07-12KPCA
WALL MOUNTED
ASYG07-12KPCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG12KPCA and is the answer not in the manual?

Fujitsu ASYG12KPCA Specifications

General IconGeneral
TypeSplit system
TimerYes
Multi-splitNo
Product colorWhite
Gas hose diameter9.52 mm
Hose length (max)20 m
Inverter technology-
Liquid hose diameter6.35 mm
Dehumidifying capacity1.8 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (nominal)3400 W
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Seasonal efficiency rating (cooling) (SEER)6.3
Seasonal efficiency rating (heating) (SCOP)4.1
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3800 W
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)3.4 kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh
Design load (heating) (Colder heating season)- kW
Design load (heating) (Warmer heating season)1.3 kW
Design load (heating) (Average heating season)2.5 kW
Energy efficiency class (heating) (Average heating season)A+
Indoor unit typeWall-mountable
Indoor unit depth224 mm
Indoor unit width784 mm
Indoor unit height270 mm
Indoor unit weight8000 g
Indoor units quantity1
Cooling airflow (indoor unit)630 m³/h
Indoor unit sound power level59 dB
Indoor unit noise level (low speed)22 dB
Indoor unit noise level (high speed)46 dB
Outdoor unit noise level- dB