6. OUTDOOR FAN CONTROL
( Table 9 : Outdoor fan speed )
*
The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
*
After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table10 without relating to the compressor freque
ncy.
01-07
( Table10 : Outdoor fan speed after the defrost )
1. Outdoor Fan Motor
2. Fan Speed
AC Motor DC Motor
07/09/12/14
Following table shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.
( Table 8 : Type of Motor )
07/09/12 900rpm
Cooling Heating
07/09
12
Y
Z
Zone
Refer to Fig.8
(rpm)
F
G
Y
Z
F
G
Dry
260/ 230/ 200
250/ 200/ 150
330/ 280/ 230
730/ 650/ 580/ 470
860/ 780/ 720/ 680/ 470
860/ 470/ 330
900/ 650/ 580/ 470 730/ 470
900/ 760/ 720/ 680/ 470 760/ 470
730/ 470/ 250
180/ 150
( Fig.8 : Outside air temperature zone selection )
21°C
10°C
Outside air
temperature rises
Outside air
temperature drops
Z zone
Y zone
F zone
G zone
12°C
C
19°C
C
14
Y
Z
F
G
300/ 230/ 200
380/ 280/ 250
850/ 750/ 670/ 500
850/ 500/ 380
950/ 850/750/ 670/550/450 760/ 470
14 950rpm
Model
Model

Other manuals for Fujitsu ASYG12LMCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG12LMCE and is the answer not in the manual?

Fujitsu ASYG12LMCE Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Inverter technologyYes
Refrigerating mediumR410A
Air conditioner functionsCooling, Dehumidifying, Heating
Refrigerating medium weight850 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 43 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Airflow750 m³/h
Outdoor unit noise level- dB
Indoor unit typeWall-mountable
Indoor unit depth204 mm
Indoor unit width870 mm
Indoor unit height270 mm
Indoor unit weight8500 g
Indoor unit noise level (high speed)43 dB
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh