SERVICE PARTS INFORMATION 1
MPa MPa
Compressor
Diagnosis method of Compressor ( If Outdoor Unit LED displays Error, refer to Trouble shooting )
Does not start up
Is there open or loose connection
cable?
Check Main PCB, connection of
Compressor, and winding resistance.
(Refer to the next page).
Check Main PCB, connection of Compressor,and winding
resistance. (Refer to the next page).
>> If there is no failure, the defect of
Compressor is considered (Locked
compressor due to clogged dirt or
less oil)
Replace Compressor
Replace Compressor
Replace Compressor
Stops soon after starting up
Is there open or loose connection
cable?
Is Gas pipe valve open?
(Low pressure is too low)
Check if Refrigerant is leaking.
(Recharge Refrigerant)
Check if capillary tube, strainer is
clogged.
(PARTS INFORMATION 3)
>> If there is no failure, the defect of Compressor can be
considered. (Compression part broken or valve defective.)
Abnormal noise
Defective Compressor
can be considered.
(due to inside dirt clogging
or broken component)
Check if vibration noise by
loose bolt or contact noise
of piping is happening.
02-25
2-4 SERVICE PARTS INFORMATION

Other manuals for Fujitsu ASYG12LMCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG12LMCE and is the answer not in the manual?

Fujitsu ASYG12LMCE Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Inverter technologyYes
Refrigerating mediumR410A
Air conditioner functionsCooling, Dehumidifying, Heating
Refrigerating medium weight850 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 43 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Airflow750 m³/h
Outdoor unit noise level- dB
Indoor unit typeWall-mountable
Indoor unit depth204 mm
Indoor unit width870 mm
Indoor unit height270 mm
Indoor unit weight8500 g
Indoor unit noise level (high speed)43 dB
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh

Related product manuals