EasyManua.ls Logo

Fujitsu ASYG14KMTA - Page 48

Fujitsu ASYG14KMTA
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Multiple outdoor unit installation
Provide at least 250 mm of space between the outdoor units if multiple units are installed.
When routing the piping from the side of an outdoor unit, provide space for piping.
No more than 3 units must be installed side by side.
When 3 units or more are arranged in a line, provide the space as shown in the following
example “When an obstruction in the upper space:”.
When the upper space is open:
Unit: mm
Obstacles at rear only Obstacles at front only
200 or more
250 or more
1,000 or more
250 or more
Obstacles at front and rear
200 or more
1,000 or more
250 or more
When an obstruction in the upper space:
Unit: mm
Obstacles at rear and above.
1,500 or more
200 or more
250 or more
250 or more
Max. 300
1,500 or more
DESIGN & TECHNICAL MANUAL
- 44 -
OUTDOOR UNIT
AOYG07-14KMTA

Table of Contents

Other manuals for Fujitsu ASYG14KMTA

Related product manuals