01-16
20. OUTDOOR UNIT LOW NOISE OPERATION
The OUTDOOR UNIT LOW NOISE Operation functions by pressing OUTDOOR UNIT LOW NOISE button
on the remote controller.
This operation stops the PFC control, and changes the Current release operation/release value.
OUTDOOR UNIT LOW NOISE Operation mode can be used during cooling, heating and automatic operation.
It can not be used in Fan and Dry mode
Control / Release
C
urrent release
operation/release value
3.5A / 3.0A
( Table 20 )
21. POWERFUL OPERATION
The POWERFUL OPERATION functions by pressing POWERFUL button on the remote controller.
The indoor unit & outdoor unit will operate at maximum power as shown in Table21.
Release Condition is as follows.
[Cooling / Dry]
- Room tenperature < Setting temperature - 0.5°C or Operation time has passed 20 minutes.
COMPRESSOR FREQUENCY Maximum
FAN CONT. MODE Powerful
SETTING LOUVER Cooling/
Dry : 3, Heating : 6
(Table21)
Powerful operation
=
=
[Heating]
- Room tenperature > Setting temperature +0.5°C or Operation time has passed 20 minutes.

Other manuals for Fujitsu ASYG14KMTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG14KMTA and is the answer not in the manual?

Fujitsu ASYG14KMTA Specifications

General IconGeneral
BrandFujitsu
ModelASYG14KMTA
CategoryAir Conditioner
LanguageEnglish

Related product manuals