02-11
Trouble shooting 8
INDOOR UNIT Error Method:
Detective Actuators: Detective details:
Forecast of Cause :
OKOK
Manual auto switch Error
Indoor unit Main PCB
Indicator PCB
Manual auto switch
When the Manual Auto Switch becomes ON for consecutive 60 or
more seconds.
1. Manual auto switch failure 2. Main PCB and Indicator PCB failure
Check Point 1 : Check the Manual auto switch
Check if Manual auto switch is kept pressed.
Check ON/OFF switching operation by using a meter.
>> If Manual auto switch is disabled (on/off switching), replace it.
Check Point 2 : Replace MainPCB and Indicator PCB
If Check Point 1 do not improve the symptom, replace Main PCB and Indicator PCB.
Indicate or Display:
Outdoor Unit : No indication
Indoor Unit : Operation lamp: 3 time Flash, Timer lamp: 5 time Flash
Economy lamp: Continuous flash.
ERROR CODE : [E : 35 ]