17. Compressor removal
06-12
Precautions for exchange of Compressor.
Do not allow moisture or debris to get inside refrigerant pipes during work.
Procedure for compressor removal.
(1) Turn off power.
(2) Remove the Panel top and Panel btm.
(3) Remove the Control Box.
(4) Fully close the 3-way valve (Gas) and (Liquid).
(5) Collect the refrigerant from the service port.
Start the following work after completely collecting the refrigerant.
Do not reuse the refrigerant that has been collected.
Remove the 4 mounting screws.
Remove the Center beam.
Remove the 4 mounting screws. Remove the Comp Box(R)
by sliding toward.
Remove the Comp Box(Top)
by sliding toward.
Remove the Comp Box(L)
by sliding toward.
Remove the 4 mounting screws.
Remove the 7 mounting screws.Loose or remove the cable ties.
(4 places)
Screws (4 places) Screws (7 places)Cable ties (4 places)
Screws
(4 places)
Screws
(4 places)