4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: AUXG09KVLA
AFR
m
3
/h
540
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 2.10 0.79 2.05 0.80 2.00 0.82 1.95 0.84 1.90 0.85
-10 -11 2.47 0.84 2.41 0.85 2.35 0.87 2.29 0.89 2.23 0.90
-5 -7 2.84 0.88 2.77 0.90 2.70 0.92 2.63 0.94 2.57 0.96
0 -2 3.44 1.04 3.36 1.06 3.28 1.08 3.20 1.10 3.12 1.12
5 3 3.91 1.13 3.81 1.16 3.72 1.18 3.63 1.20 3.53 1.23
7 6 4.10 1.17 4.00 1.20 3.90 1.22 3.80 1.24 3.71 1.27
10 8 4.20 1.18 4.10 1.21 4.00 1.23 3.90 1.25 3.80 1.28
15 10 4.48 1.21 4.38 1.23 4.27 1.26 4.16 1.29 4.06 1.30
20 15 4.45 1.03 4.35 1.05 4.24 1.07 4.13 1.09 4.03 1.11
24 18 4.47 0.92 4.37 0.94 4.26 0.96 4.15 0.98 4.05 0.99
¢
Model: AUXG12KVLA
AFR
m
3
/h
600
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 2.59 0.91 2.53 0.93 2.47 0.95 2.41 0.97 2.35 0.99
-10 -11 2.87 0.95 2.80 0.97 2.73 0.99 2.66 1.01 2.59 1.03
-5 -7 3.24 0.98 3.17 1.00 3.09 1.02 3.01 1.04 2.94 1.06
0 -2 3.85 1.15 3.76 1.18 3.67 1.20 3.58 1.22 3.49 1.25
5 3 4.40 1.28 4.29 1.30 4.19 1.33 4.09 1.36 3.98 1.38
7 6 4.62 1.32 4.51 1.35 4.40 1.38 4.29 1.41 4.18 1.44
10 8 4.78 1.27 4.66 1.29 4.55 1.32 4.44 1.35 4.32 1.37
15 10 5.04 1.17 4.92 1.20 4.80 1.22 4.68 1.24 4.56 1.26
20 15 4.87 1.23 4.76 1.25 4.64 1.28 4.52 1.31 4.41 1.32
24 18 5.04 1.11 4.92 1.14 4.80 1.16 4.68 1.18 4.56 1.20
¢
Model: AUXG14KVLA
AFR
m
3
/h
800
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 3.15 1.13 3.08 1.16 3.00 1.18 2.93 1.20 2.85 1.23
-10 -11 3.66 1.21 3.58 1.23 3.49 1.26 3.40 1.29 3.32 1.31
-5 -7 4.22 1.30 4.12 1.32 4.02 1.35 3.92 1.38 3.82 1.40
0 -2 5.15 1.56 5.02 1.59 4.90 1.62 4.78 1.65 4.66 1.68
5 3 5.42 1.66 5.29 1.70 5.16 1.73 5.03 1.76 4.90 1.80
7 6 5.57 1.54 5.43 1.57 5.30 1.60 5.17 1.63 5.04 1.66
10 8 5.74 1.56 5.61 1.59 5.47 1.62 5.33 1.65 5.20 1.68
15 10 5.87 1.45 5.73 1.48 5.59 1.51 5.45 1.54 5.31 1.56
20 15 5.44 1.13 5.31 1.16 5.18 1.18 5.05 1.20 4.92 1.22
24 18 5.75 1.14 5.62 1.17 5.48 1.19 5.34 1.21 5.21 1.23
¢
Model: AUXG18KVLA
AFR
m
3
/h
800
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 3.86 1.16 3.77 1.19 3.68 1.21 3.59 1.23 3.50 1.26
-10 -11 4.39 1.24 4.28 1.26 4.18 1.29 4.08 1.32 3.97 1.34
-5 -7 4.91 1.32 4.80 1.35 4.68 1.38 4.56 1.41 4.45 1.44
0 -2 5.93 1.61 5.79 1.65 5.65 1.68 5.51 1.71 5.37 1.75
5 3 6.36 1.71 6.21 1.74 6.06 1.78 5.91 1.82 5.76 1.85
7 6 6.62 1.76 6.46 1.79 6.30 1.83 6.14 1.87 5.99 1.90
10 8 6.98 1.79 6.82 1.82 6.65 1.86 6.48 1.90 6.32 1.93
15 10 7.59 1.82 7.41 1.86 7.23 1.90 7.05 1.94 6.87 1.97
20 15 6.95 1.50 6.79 1.53 6.62 1.56 6.45 1.59 6.29 1.61
24 18 6.89 1.51 6.72 1.54 6.56 1.57 6.40 1.60 6.23 1.63
- 11 -
4-2. Heating capacity 4. Capacity table
CASSETTE TYPE
AUXG09-22KVLA
CASSETTE TYPE
AUXG09-22KVLA