EasyManua.ls Logo

Fujitsu ETERNUS DX600 S5 - User Manual

Fujitsu ETERNUS DX600 S5
335 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
FUJITSU Storage
ETERNUS DX S5 series
Hybrid Storage Systems
Design Guide
Functions / features / system configuration design
P3AG-3972-02ENZ0

Table of Contents

Other manuals for Fujitsu ETERNUS DX600 S5

Questions and Answers

  • K
    Keith McgrathAug 5, 2025
    Why is my Fujitsu ETERNUS DX600 S5 Storage ETERNUS DX not connecting via network service?
    • T
      theresa76Aug 5, 2025
      If your Fujitsu Storage ETERNUS DX cannot be connected via a network service, consider the following: * Ensure the ETERNUS DX is powered on. * Verify the LAN cable is properly connected. * Check for any failed network devices, such as a LAN switch or router. * Confirm that the network service environment settings are valid. * Ensure the IP address is correct. * Verify the settings for the ETERNUS DX LAN ports (firewall) are valid.
  • M
    Michele WilliamsAug 9, 2025
    What to do if my Fujitsu ETERNUS DX600 S5 Storage ETERNUS DX refuses to turn on?
    • L
      levineelizabethAug 9, 2025
      If your Fujitsu Storage ETERNUS DX refuses to turn on, please check the following: * Ensure the power cord is connected properly. * Verify the PSU switch of the power supply unit is turned to the ON position. * Confirm the main line switch of the power distribution unit is not turned OFF. * Check for any power failures. * Ensure the mini SAS HD cable between enclosures is connected.
  • M
    Michael NelsonAug 13, 2025
    Why is I/O access slow on my Fujitsu Storage?
    • M
      Margaret JonesAug 13, 2025
      If you are experiencing slow I/O access on your Fujitsu Storage, consider the following checks: 1. Ensure the ambient temperature is within operating environment conditions. 2. Check the battery status using ETERNUS Web GUI. 3. Use ETERNUS Web GUI to check for abnormalities in each component on the [Storage] screen of [Component]. 4. Check the path status. 5. If using ETERNUS Multipath Driver, start ETERNUS Multipath Manager. 6. Check the loading of the ETERNUS DX. 7. Check the transfer rate of the FC port. 8. Check the number of command queues in the server. 9. Check the message log of the OS on the connected server. 10. Check the status of the RAID group. 11. Check the cache parameter settings of the volumes.
  • B
    Bernard BellAug 18, 2025
    What to do if FAULT LED Is On on Fujitsu Storage?
    • E
      Erin SmithAug 18, 2025
      If the FAULT LED is illuminated on your Fujitsu Storage, try the following: * Check the general status and system messages in the ETERNUS Web GUI. * Verify that the mini SAS HD cable between enclosures is properly connected on both sides. * Check the connection of the mini SAS HD cable between enclosures. * Ensure that the l (IN) and n (OUT) sides of the mini SAS HD cable between enclosures are connected correctly.
  • K
    Kristopher HowardAug 22, 2025
    What to do if server does not recognize volumes on Fujitsu ETERNUS DX600 S5?
    • A
      Amanda ButlerAug 22, 2025
      If the server does not recognize the volumes on your Fujitsu Storage, you should: * Check the status of the ETERNUS DX and other devices, including network devices, connecting the server and the ETERNUS DX. * Check for errors in the path using a path management tool like ETERNUS Multipath Manager.
  • J
    Jonathan HughesAug 27, 2025
    How to reconnect mini SAS HD cable on Fujitsu ETERNUS DX600 S5 Storage?
    • T
      Tyler RayAug 27, 2025
      When a mini SAS HD cable between enclosures is not connected: * Press the controller enclosure's Power switch for four seconds or more to turn off the ETERNUS DX. * Connect the mini SAS HD cable between enclosures while the drive enclosure is on. * Press the controller enclosure's Power switch to turn on the ETERNUS DX.
  • C
    Cassandra DavisAug 30, 2025
    What to do if mini SAS HD cable is incorrectly connected on Fujitsu ETERNUS DX600 S5 Storage?
    • V
      Valerie RamirezAug 31, 2025
      When the l (IN) and n (OUT) sides of the mini SAS HD cable between enclosures are incorrectly connected or the cable is connected in the wrong order: * Press the controller enclosure's Power switch for four seconds or more to turn off the ETERNUS DX, and turn off the AC power. * Reconnect the mini SAS HD cable between enclosures. * Make sure that AC power is being supplied, then turn the ETERNUS DX on.

Fujitsu ETERNUS DX600 S5 Specifications

General IconGeneral
ModelETERNUS DX600 S5
Form Factor2U
RAID Levels Supported0, 1, 5, 6, 10, 50, 60
Supported Drive TypesSAS, SATA, SSD
ControllerDual Controller
Connectivity16 Gb/s FC, 10 Gb/s iSCSI, 12 Gb/s SAS
Power SupplyRedundant power supplies
Operating Humidity20% to 80% (non-condensing)
Drive Bays60
Host InterfaceFibre Channel, iSCSI, SAS

Related product manuals