ETERNUS DX60 S2
Support and Maintenance
Support and Maintenance ETERNUS DX60 S2

Other manuals for Fujitsu ETERNUS DX60 S2

Questions and Answers

  • J
    Jaclyn DavisAug 19, 2025
    What to do if FAULT LED is blinking on Fujitsu ETERNUS DX60 S2?
    • Z
      zleeAug 19, 2025
      If the FAULT LED is blinking on your Fujitsu Storage, check the general status in ETERNUS Web GUI. A general status indicates that a component requires preventive maintenance.
  • K
    Kevin SuarezAug 21, 2025
    What to do if FAULT LED is on Fujitsu ETERNUS DX60 S2 Storage?
    • T
      Tara RobertsAug 21, 2025
      If the FAULT LED is on for your Fujitsu Storage, check the general status of ETERNUS Web GUI and perform the necessary action. If the problem persists, leave the ETERNUS DX Disk storage system alone and contact your maintenance engineer.
  • D
    Dawn MillerAug 23, 2025
    What to do if READY LED is not on Fujitsu Storage?
    • R
      Ryan WillisAug 23, 2025
      If the READY LED is not on after more than ten minutes since turning on the power of your Fujitsu Storage, contact your maintenance engineer.
  • C
    Carlos StevensAug 26, 2025
    How to fix Fujitsu ETERNUS DX60 S2 when it cannot connect via a network service?
    • A
      Aaron McintoshAug 26, 2025
      If your Fujitsu Storage system cannot be connected via a network service, first verify that the system is powered on. Then, check the LAN cable connection and ensure that network devices like LAN switches or routers are functioning correctly with valid settings. Also, confirm that the network service environment settings and the IP address are correct. Finally, check the LAN port environment settings for the Fujitsu Storage system. If problems persist, you may need to revert the network settings to their default values.
  • L
    Lisa MolinaAug 28, 2025
    What to do if Fujitsu ETERNUS DX60 S2 Storage refuses to turn on?
    • M
      Mrs. Ariel Johnson PhDAug 28, 2025
      If your Fujitsu Storage system refuses to turn on, start by checking the power cord to ensure it is properly connected. Next, verify that the main line switch of the power distribution unit is turned to the ON position. Also, check for any power failures in your location. Finally, inspect the miniSAS cable (for drive enclosures) to ensure it is securely connected.
  • D
    Daniel ZimmermanAug 30, 2025
    Why is my Fujitsu Storage turning off?
    • R
      ronald04Aug 30, 2025
      If your Fujitsu Storage system is turned off unexpectedly, start by checking the power cord to ensure it's properly connected. Next, verify that the main line switch of the power distribution unit is in the ON position. If the storage system is connected to a power synchronized unit, it might turn off when the server is turned off. Also, check for any power failures. If the system is in AC automatic power mode, it should turn on automatically once power is restored after an outage.
  • L
    Lynn OlsenSep 2, 2025
    How to troubleshoot slow I/O access on Fujitsu Storage?
    • D
      Derrick JenkinsSep 2, 2025
      If I/O access is slow on your Fujitsu Storage system, begin by checking that the ambient temperature is within the specified operating conditions. Next, use the Storage System Status screen in ETERNUS Web GUI to check for any abnormalities in the system parts. Also, check the path status. If you are using the ETERNUS Multipath Driver, start ETERNUS Multipath Manager; otherwise, use a path management tool to check the path status. Verify the system's loading and adjust the number of command queues in the server. If the transfer speed of the FC port differs from the server or FC switch, set them to the same speed.
  • O
    ojohnsonSep 4, 2025
    What to do if server doesn't recognize volumes on Fujitsu ETERNUS DX60 S2?
    • G
      gonzaleznicholasSep 4, 2025
      If the server does not recognize the volumes on your Fujitsu Storage, check the status and power supply of the storage system and any connecting network devices to ensure they are functioning correctly. Also, use a path management tool, such as ETERNUS Multipath Manager, to check for any errors in the path.
  • H
    Haley HillSep 6, 2025
    What to do if FAULT LED is on in Fujitsu Storage?
    • G
      George RomanSep 6, 2025
      Check the general status of ETERNUS Web GUI and perform the necessary action.
  • J
    Jonathan JohnsonSep 8, 2025
    What does blinking FAULT LED mean on Fujitsu ETERNUS DX60 S2?
    • M
      Michael TapiaSep 8, 2025
      Check the general status in ETERNUS Web GUI. A general status of indicates that the Fujitsu Storage system contains a component that requires preventive maintenance.

Summary

Maintenance Operations

Device Status

Displays the current status of system components and their states.

Preventive Maintenance

Procedures for maintaining system health and preventing issues.

Force Degrade

Command to degrade a component to a lower state.

Force Reboot

Command to force a reboot of a component.

Hot Reduction

Process for reducing capacity or components without downtime.

Identify LED

Function to identify specific hardware components using LEDs.

Maintenance Utilities

Start; End Maintenance

Initiates and concludes maintenance operations on the system.

Add Drive Enclosure

Extends the system by adding a new drive enclosure.

Remove Drive Enclosure

Reduces system capacity by removing a drive enclosure.

Add Controller Module

Extends system functionality by adding a controller module.

Delete Sense Data

Clears sense data from hosts after component replacement.

Log and Dump Management

Event Log

Displays the history of events that occurred in the device.

Export Panic Dump

Acquires memory information on failure for analysis.

Error Information

Shows error frequency for disks and ports.

Export Log

Exports and saves device maintenance information.

Export Configuration

Outputs system composition and setup information.

Get G-List

Gathers grown defect list information from disk management.

Utilities

Shutdown;Restart System

Shuts down or restarts the system.

Initialize System Disk

Initializes the system disk.

Manage Pinned Data

Manages pinned data not written to disk.

Apply Configuration

Applies configuration data from an external file.

Change Master CM

Changes the master controller module.

Disk Diagnosis

Performs diagnostic tests on disk drives.

Maintenance Procedures

Maintenance and Status LEDs

Explains the meaning of LEDs for maintenance status indication.

Set System to Maintenance Mode

Puts the system into maintenance mode for specific operations.

Replacement Procedures

Start Hot Maintenance

Initiates hot maintenance for component replacement.

Typical Installation Times

Details typical installation times for various system components.

Verify Status Change

Verifies that component status changes back to normal after replacement.

Collecting Internal Log

Collects internal logs as proof of replacement operation.

Change System Back to Normal State

Returns the system to its normal operational state after maintenance.

Log Off

Safely logs off from the ETERNUS Web GUI.

Additional Reading

Maintenance Manual

Provides detailed technical information for the ETERNUS system.

Fujitsu Support Portal

Offers support-related information for Fujitsu disc storage.

Fujitsu ETERNUS DX60 S2 Specifications

General IconGeneral
BrandFujitsu
ModelETERNUS DX60 S2
CategoryStorage
LanguageEnglish

Related product manuals