EasyManua.ls Logo

Fujitsu fi-7180 - Settings Related to Scanning; Adjusting the Position to Start the Scan [Offset;Vertical Magnification Adjustment]

Fujitsu fi-7180
229 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 Operational Settings
Appendix
Glossary
Introduction
Index
Contents
TOP
183
How to Load
Documents
Configuring the
Scan Settings
How to Use the
Operator Panel
Various Ways to
Scan
Daily Care
Troubleshooting
Replacing the
Consumables
Scanner
Overview
Operational
Settings
Adjusting the Position to Start the Scan
[Offset/Vertical magnification Adjustment]
When the output position of the scanned image is not correct or
the image appears shortened/elongated (vertically), adjust the
offset and the vertical magnification in the following procedure.
1 Start up the Software Operation Panel.
For details, refer to "9.1 Starting Up the Software Operation Panel"
(page 163).
2 From the listing on the left, select [Device Setting] and
click the [Offset] button.
3 Adjust the level of offset/vertical magnification as needed.
9.5 Settings Related to Scanning
ATTENTION
Normally, you should not have to make any adjustments as the factory
default settings are configured at appropriate values.
Offset Setting Description
Unit Select [Flat bed] (fi-7260/fi-7280), [ADF (front)]
or [ADF (back)] as the target for offset
adjustment.
Main Adjusts the horizontal (width) offset.
The value can range from -2 to +2 mm (in
increments of 0.5).
Sub Adjusts the vertical (length) offset.
The value can range from -2 to +2 mm (in
increments of 0.5).

Table of Contents

Other manuals for Fujitsu fi-7180

Related product manuals