EasyManua.ls Logo

Fujitsu General ARXG45KHTB

Fujitsu General ARXG45KHTB
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Available Sensor ID
Sensor ID Item Unit Remarks
00 140 Operation or Stop (External input) 00: —
0: Off, 1: On
—: When the function setting 46 is
not set
NOTE: Available only for external
input port of the indoor unit
00 141 Emergency stop (External input) 00: —
0: Off, 1: On
—: When the function setting 46 is
not set
NOTE: Available only for external
input port of the indoor unit
00 142 Forced stop (External input) 00: —
0: Off, 1: On
—: When the function setting 46 is
not set
NOTE: Available only for external
input port of the indoor unit
00 143 Operation or Stop 2 (External input) 00: —
0: Off, 1: On
—: When the function setting 46 is
not set
NOTE: Available only for external
input port of the indoor unit
00 144
External thermostat off (External
input)
00: — 0: Off, 1: On
00 145 Cooling operation on (External input) 00: — 0: Off, 1: On
00 146
Cooling operation off (External
output)
00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
00 155
Operation or Stop On/Off (External
output)
00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
00 156 Error On/Off (External output) 00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
00 157
Indoor unit fan interlocking On/Off
(External output)
00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
00 158
Cooling thermostat On/Off (External
output)
00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
00 159
Requested cooling strength On/Off
(External output)
00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
00 160
External heater On/Off (External
output)
00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
00 161
Heating operation status (External
output)
00: —
0: Off, 1: On
NOTE: The value is output even if
the function setting or
rotary switch is not set.
6-13. Unit status monitoring and the detected value indication
- (04-25) - 6. Various control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Related product manuals