1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
13°C
E zone
7°C
D zone
°C
C zone
B zone
A zone
-5
2
°C
-10°C
G zone
21°C
J zone
50°C
K zone
52°C
H zone
31°C
I zone
46°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOHG45KRTA
AOHG54KRTA
A zone 50 rps
B zone 47 rps
C zone 40 rps
D zone 30 rps
E zone 22 rps
F zone 20 rps
G zone 16 rps
H zone 16 rps
I zone 17 rps
J zone 23 rps
K zone 28 rps
1-5. Rotation number of compressor limitation by outdoor temperature - (04-4) - 1. Rotation number control of compressor