EasyManua.ls Logo

Fujitsu General ARXG45KHTB

Fujitsu General ARXG45KHTB
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
13°C
E zone
7°C
D zone
°C
C zone
B zone
A zone
-5
2
°C
-10°C
G zone
21°C
J zone
50°C
K zone
52°C
H zone
31°C
I zone
46°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOHG45KRTA
AOHG54KRTA
A zone 50 rps
B zone 47 rps
C zone 40 rps
D zone 30 rps
E zone 22 rps
F zone 20 rps
G zone 16 rps
H zone 16 rps
I zone 17 rps
J zone 23 rps
K zone 28 rps
1-5. Rotation number of compressor limitation by outdoor temperature - (04-4) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Related product manuals