1-4. Rotation number of compressor at normal start-up
¢ Model: AOHG18KMTA
Rotation number of compressor soon after starting is controlled as below.
Rotation number I
Rotation number II
Rotation number III
Rotation number IV
Rotation number V
Time 1
Time 2 Time 3
Time 4
Time 5
Rotation number
(rps)
I II III IV V
32 56 77 90 99
Time (sec)
1 2 3 4 5
60 240 280 360 400
¢ Model: AOHG24KMTA
Rotation number of compressor soon after starting is controlled as below.
Frequency I
Frequency II
Frequency III
Frequency IV
Frequency V
Frequency VI
Time 1
Time 2 Time 3
Time 4
Time 5
Time 6
Rotation
number (rps)
I II III IV V VI
29 52 64 71 89 97
Time (sec)
1 2 3 4 5 6
60 140 170 200 350 410